EasyManua.ls Logo

HP StorageWorks P9000

HP StorageWorks P9000
333 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 50 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WCheck the status of the
specified M-VOL.
The specified M-VOL must not be in an
intervention-required condition, in a
protection condition, in an unusable
condition, the Business Copy/Business
Copy Z T-VOL/reserved volume or a
reserved volume of Auto LUN.
89216005
WDelete the LUs defined on
the specified port, then retry
the operation.
Logical paths exist on the RCU port.89246005
WConfirm the status of Volume
Security for Mainframe of
the specified R-VOL.
The specified R-VOL is prohibited to use
by Volume Security for Mainframe.
89266005
WConfirm the status of Volume
Security for Mainframe of
the specified M-VOL.
The specified M-VOL is prohibited to
use by Volume Security for Mainframe.
89276005
WRefresh the window, then
retry the operation.
If the same problem persists
despite retrying, please
contact HP Technical
Support.
Invalid port type.89296005
WDelete the LUs defined on
the specified port, then retry
the operation.
Logical paths exist on the RCU port.89306005
WDelete the LUs defined on
the specified port, then retry
the operation.
Logical paths exist on the RCU port.89316005
WCheck whether the specified
LDKC number or CU number
is defined as configuration
information of the MCU.
Since the configuration definition of the
specified LDKC number or CU number
does not exist, the logical paths
between MCU and RCU cannot be
established.
89326005
WCheck the configuration of
the specified R-VOL.
The Paircreate operation failed because
specified R-VOL is the NAS system
volume.
89346005
WCheck the microcode version
of the RCU.
The Paircreate operation failed. The
version of the specified RCU does not
support Remote Copy with the NAS
volume.
89366005
WCheck the LUN of the
specified M-VOL by using
RAID Manager, and specify
the LUN with the value less
than 1,024 for the M-VOL.
The specified M-VOL cannot be used.89396005
WConfirm the status of the
specified R-VOL.
The operation failed because the
specified R-VOL was in a Read Only
status by Volume Retention.
89406005
Part code 6005 157