Table 50 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WRefresh the window a few
minutes later, and check the
status of the specified
volume and other volume(s)
of the same group in the
RCU. If it is possible to
perform operations on the
volume(s), retry the
operation.
The specified volume or other volume(s)
of the same group in the RCU is being
changed to Simplex/Suspend status.
Retry the operation a few minutes later.
89436005
WCheck the status of the
specified R-VOL.
The specified R-VOL is not available
according to the attribute of the R-VOL
changed by Data Retention.
89446005
WVerify that the M-VOL
parameters (CU number,
Port, GID, and LUN) are
supported with the RCU
microcode program version.
Verify that the SSID and CU
number of RCU and the
R-VOL parameters (Port,
GID, and LUN) are correct.
If you create a pair by using
a LUSE volume, verify that
two or more CU numbers
coexist in P-VOL and S-VOL.
Specify RCUs of CU Free
when two or more CU
numbers coexist in P-VOL or
S-VOL.
Then, retry the operation
using the correct parameters.
At least one of the following is invalid:
M-VOL parameters (CU number,
Port, GID, LUN)
SSID or CU number of the RCU
R-VOL parameters (Port, GID, LUN)
89456005
WRelease the setting of the
external volume, then retry
the operation.
The external volume that is mapped to
an internal volume is connected to the
port.
89476005
WStop I/O operations, then
retry.
The specified port is receiving I/O
requests.
89486005
EPlease contact HP Technical
Support.
An internal error occurred.89496005
EPlease contact HP Technical
Support.
An internal error occurred.89506005
WCheck the status of the
specified R-VOL.
The operation failed because the
specified R-VOL was used for XP Flex
Copy.
89736005
WCheck the status of the
specified R-VOL.
Failed to create a pair, because the
specified R-VOL is path-defined from
the iSCSI port.
89756005
WCheck the status of the
specified M-VOL.
A pair cannot be created, because the
specified M-VOL is an external volume.
89766005
WCheck the status of the
specified R-VOL.
A pair cannot be created, because the
specified R-VOL is an external volume.
89776005
158 Message (part code group 6nnn)

Table of Contents