Table 50 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WConfirm the licensed
capacity Mainframe Array
Management on the RCU
side. To execute this
operation, purchase a
license key that allows you
to use a larger capacity.
The operation failed because the
licensed capacity of Mainframe Array
Management on the RCU side was
exceeded.
89806005
WSpecify the volume that can
be used to create a pair,
then retry the operation.
You cannot create a pair, because the
specified M-VOL is a command device.
89826005
WSpecify the volume that can
be used to create a pair,
then retry the operation.
You cannot create a pair, because the
specified R-VOL is a command device.
89836005
EPlease contact HP Technical
Support.
You cannot create a new pair, because
the number of CT groups of
asynchronous pairs that you can
register in SLPR exceeds the limit.
89846005
iCheck the settings, then retry
the operation.
The coexistence of volumes that are in
the different CLPRs is not allowed within
one CT group.
89856005
WVerify that both MCU and
RCU support LUSE volumes
that consist of volumes from
different CUs.
Cannot create a pair, because LUSE
volumes consisting of volumes from
different CUs are not supported by
either the MCU or the RCU.
89876005
WVerify that both MCU and
RCU support LUSE volumes
consisting of volumes that
differ in capacity.
Cannot create a pair, because LUSE
volumes consisting of volumes that differ
in capacity are not supported by either
the MCU or the RCU.
89886005
WCheck the version of the
microcode of the storage
system.
If the microcode of the
storage system supports the
interface between
Compatible FlashCopy and
M-VOL of Continuous Access
Synchronous Z, then check
the setting of "Difference
Management" of the
specified volume.
If microcode version or the
setting does not match the
above description, check
whether the specified volume
belongs to Sync Group from
Business Continuity
Manager.
The specified M-VOL is a volume used
by Compatible FlashCopy.
The operation failed because of one of
the following reasons.
• The current microcode cannot use a
volume used by Compatible
FlashCopy as an M-VOL.
• "Cylinder" was set for the
"Difference Management" of the
M-VOL.
• The M-VOL belonged to Sync
Group.
89896005
WSpecify the volume that can
be used to create a pair,
then retry the operation.
A pair cannot be created, because the
specified R-VOL is used for Compatible
FlashCopy.
89906005
EPlease contact HP Technical
Support.
The attribute of the port assigned to
SLPRs except SLPR0 can only be
changed to Target.
552306005
Part code 6005 159