Table 50 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
EPlease contact HP Technical
Support.
This function cannot be used by the
storage partition administrator.
565246005
EIf the problem persists
despite retrying, please
contact HP Technical
Support.
An error occurred during SVP
processing.
570056005
WSelect another volume, and
retry the operation.
A pair cannot be created because the
specified M-VOL is used by Continuous
Access Journal or Continuous Access
Journal Z.
583196005
WIf the Add Pair (Paircreate)
operation failed:
When the RCU runs on
the 2DC configuration in
which the Continuous
Access Journal
cooperates, wait for a
while until the pair status
of the Continuous Access
Journal becomes “PAIR,
then retry the operation.
When the RCU runs on
the configuration other
than the 2DC
configuration in which
the Continuous Access
Journal cooperates,
specify another volume
for R-VOL, then retry the
operation.
If the Pairresync operation
failed, resume the
Continuous Access Journal
pair volume first.
The operation failed because the
specified R-VOL was used by
Continuous Access Journal or
Continuous Access Journal Z.
583206005
WSelect another volume and
retry the operation.
The pair cannot be created because the
specified M-VOL is a LUSE volume that
is set across multiple CLPRs.
583216005
WSelect another volume, and
retry the operation.
The pair cannot be created because the
specified R-VOL is a LUSE volume that
is set across the multiple CLPRs.
583226005
WCheck to ensure that you did
not mistakenly attempt to
create a volume with or
without VMA.
A pair cannot be created, because you
tried to create a volume pair formed
with a volume to which VMA is set by
Data Retention and a volume without
VMA.
583576005
WWait a while, then retry the
operation.
A pair cannot be created, because the
set processing of VMA that is used for
Data Retention has not been completed
for the specified P-VOL.
583586005
WWait a while, then retry the
operation.
A pair cannot be created, because the
set processing of VMA that is used for
Data Retention has not been completed
for the specified S-VOL.
583596005