Table 50 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WRefresh the window, and
confirm whether the
specified volume is an
External Storage Access
Manager pair volume.
The operation failed because the
specified volume was not an External
Storage Access Manager pair volume.
687926005
WRefresh the window, and
confirm whether the status of
the specified volume is
SSWS.
The Reverse Resync operation failed
because the status of the specified
volume was not SSWS.
687936005
WCreate a path from the RCU
to the MCU.
The operation failed because the path
from the RCU to the MCU did not exist.
687946005
EContact the Support Center,
and check the shared
memory.
The operation failed. The shared
memory might be insufficient.
Please contact HP Technical Support.
687956005
WRefresh the window, and
confirm the pair status of the
specified volume.
The operation failed. The operation
cannot be accepted in the pair status
of the specified volume.
687966005
WCheck each capacity of the
M-VOL and the R-VOL after
the capacity change of
R-VOL ends, and plan a
combination of volumes for
pair creating.
A pair could not be created because
the specified R-VOL was a Thin
Provisioning volume whose capacity
was being changed.
688126005
WCheck each capacity of the
M-VOL and the R-VOL after
the capacity change of
M-VOL ends, and plan a
combination of volumes for
pair creating.
A pair could not be created because
the specified M-VOL was a Thin
Provisioning volume whose capacity
was being changed.
688136005
WThe specified volume is a
primary data volume of the
Continuous Access Journal,
which runs on the 2DC
configuration in which the
Continuous Access
Synchronous or External
Storage Access Manager
cooperates. Specify another
volume.
A pair cannot be created because the
specified volume is used as a primary
data volume of the Continuous Access
Journal.
688166005
WThe RCU runs on the 2DC
configuration in which the
Continuous Access Journal
cooperates.
Set "Track" to the
"Difference Management,"
then retry the operation.
The specified R-VOL was a pair volume
of the Continuous Access Journal.
A pair could not be created because
"Cylinder" was set to the "Difference
Management."
688176005
WInstall the External Storage,
then retry the operation.
The operation failed, because the
External Storage function was not
installed.
688266005