Table 52 Error codes (part code 6010) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
iTo continue processing, click [OK]. To
stop processing, click [Cancel].
The monitoring data currently saved will
be deleted when you change the setting
of the monitoring switch. If necessary,
use the Export Tool to save the
monitoring data.
The monitoring data saved at present
will be deleted when the monitoring
switch is set to Enable the next time.
590316010
WTo continue the operation, click [OK].
Otherwise, click [Cancel].
[Warning]
This operation deletes all command
devices for the Business Continuity
Manager. Are you sure you want to
continue this operation?
593406010
WSpecify the correct LDKC number.The specified LDKC number is incorrect.
Specify the correct LDKC number.
656636010
WSpecify another volume.The specified volume is not valid for this
program product. Specify another
volume.
656646010
WCheck the monitoring setting.The specified volume is not the volume
to be monitored. Check the monitoring
setting.
656656010
WRegister some quorum disk IDs, then retry
the operation.
There are no quorum disk IDs available.
Register some quorum disk IDs, then retry
the operation.
657696010
WRegister some RCUs of CU Free, then
retry the operation.
There are no RCUs available. Register
some RCUs of CU Free, then retry the
operation.
657706010
WCreate some external volumes, then retry
the operation.
There are no external volumes that can
be used as a quorum disk. Create some
external volumes, then retry the
operation.
657716010
WAssign another external volume not used
in the quorum disk IDs, then retry the
operation.
An external volume is assigned to two
or more quorum disk IDs. An external
volume cannot be used for multiple
quorum disk IDs.
657726010
WSelect a RCU and a quorum disk ID that
have the same serial number and the
controller ID, then retry the operation.
The serial number and the controller ID
of the RCU registered in a quorum disk
do not correspond with the specified
RCU.
657736010
WSelect the quorum disk ID corresponding
with the serial number and the controller
ID of the RCU that which is used by the
specified pair, then retry the operation.
The serial number and the controller ID
of the RCU registered in a quorum disk
do not correspond with the information
of RCU used by the specified pair.
657746010
WSpecify the quorum disk ID, then retry
the operation.
The quorum disk ID was not specified.
When the [Change attribute to ESAM]
parameter has been changed from [No]
to [Yes], specify the quorum disk ID.
658046010
WCheck the LDKC number for the specified
data volume, and specify only one LDKC
number.
There are two or more LDKC numbers
for the specified data volume. In this
operation, please specify only one LDKC
number.
690186010
174 Message (part code group 6nnn)