Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the configuration of the specified
secondary data volume.
The specified secondary data volume is
used as a command device.
583066505
WCheck the configuration of the specified
secondary data volume.
The specified secondary data volume is
an On-Demand (Just in Time) volume.
583076505
WCheck the configuration of the primary
data volume.
The specified primary data volume is
used as a command device.
583086505
WConfirm the controller type of the RCU.The Add Pair (Paircreate) operation
failed because the specified primary
data volume was a P-VOL of Continuous
Access Synchronous or External Storage
Access Manager or an M-VOL of
Continuous Access Synchronous Z.
583246505
WCheck the status of the specified primary
data volume in the Continuous Access
Synchronous, External Storage Access
Manager, or the Continuous Access
Synchronous Z window.
If the primary data volume is in PSUS,
PSUE or Suspend status, restore the
volume, then retry the operation.
If the primary data volume is in COPY
or Pending status, retry the operation
after the status of the volume changes to
PAIR or Duplex.
The specified primary data volume is
used by Continuous Access Synchronous,
External Storage Access Manager, or
Continuous Access Synchronous Z. The
operation failed because the status of
the Continuous Access Synchronous pair,
the External Storage Access Manager
pair, or the Continuous Access
Synchronous Z pair was inappropriate.
583256505
WSpecify another primary data volume,
and retry the operation.
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was shared by Continuous
Access Synchronous (or Continuous
Access Synchronous Z) and Business
Copy (or Business Copy Z).
583266505
WSpecify another primary data volume,
and retry the operation.
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was an LUSE volume.
583276505
EPlease contact HP Technical Support.The operation of Add Pair (Paircreate)
or Resume Pair (Pairresync) cannot be
performed, because the data are
remained in the journal cache for the
restore journal.
583286505
EPlease contact HP Technical Support.The operation of Add Pair (Paircreate)
or Resume Pair (Pairresync) cannot be
performed, because the data are
remained in the journal cache for the
master journal.
583296505
WCheck the attribute of the specified
journal.
The parameter related to the inflow
cannot be changed, because the
specified journal is a restore journal.
583336505
WCheck the status of the specified journal.The parameter related to the inflow
cannot be changed, because the status
of the specified journal is neither "Initial"
nor "Stopped."
583346505
WCheck the status of the specified journal.The timer type cannot be changed,
because the status of the specified
journal is not "Initial."
583356505