Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the mirror status of the specified
journal.
The journal volume cannot be deleted
from the specified journal due to the
mirror status.
586976505
WCheck the status of the secondary data
volume.
The operation failed because the
specified secondary data volume was
used by Delta resync.
586986505
WCheck the status of the specified
secondary data volume in the Business
Copy/Snapshot window, the Business
Copy Z window, or the Compatible
FlashCopy window.
The operation to change the status to the
status ready for Delta resync failed
because the specified secondary data
volume was used by one of the following
program products.
• Business Copy/Snapshot
• Business Copy Z
• Compatible FlashCopy
586996505
WCheck the status of the specified
secondary data volume.
The operation to change the status to the
status ready for Delta resync failed.
The specified secondary data volume
should meet the following requirements.
• The specified volume is a secondary
data volume of another mirror.
• The pair status of the specified volume
is PAIR or Duplex.
587006505
WDelta resync cannot be executed. Delete
the pair ready for Delta resync and copy
all data in the primary data volume.
The Delta resync operation failed,
because journal data of the master
journal were insufficient.
587016505
WCheck the number of pairs for each
mirror of the restore journal.
The Delta resync operation failed,
because the number of pairs for each
mirror of the restore journal was
different.
587026505
WDelta resync cannot be executed. Delete
the pair ready for Delta resync and copy
all data in the primary data volume.
The Delta resync operation failed
because the secondary data volume was
updated.
587036505
WCheck the status of the data volumes in
the Continuous Access Synchronous,
Continuous Access Synchronous Z,
Continuous Access Journal or the
Continuous Access Journal Z window.
The operation to change the status to the
status ready for Delta resync failed
because the status of the volumes was
one of the following:
• The P-VOL for Continuous Access
Synchronous or External Storage
Access Manager and the primary
data volume for Continuous Access
Journal are different.
• The M-VOL for Continuous Access
Synchronous Z and the primary data
volume for Continuous Access Journal
Z are different.
587046505
Part code 6505 203