Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WIf the problem persists despite retrying,
contact HP Technical Support.
The status of the other mirror of the Delta
resync did not change.
586876505
WCheck the status of the specified primary
data volume.
Delta resync failed because the specified
primary data volume was not ready for
Delta resync.
586886505
WCheck the status of the mirrors in the
specified journal.
The operation failed, because the status
of some mirrors in the master or restore
journal was invalid. Check the status of
the mirrors in the specified journal.
586896505
WCheck the status on the primary data
volume.
The recovery to the status ready for Delta
resync failed, because the status of the
specified primary data volume was one
of the following:
The primary data volume is being
copied; correction copy or drive copy
is in progress.
The primary data volume is in
correction access status.
The primary data volume is blocked
The primary data volume is being
maintained.
The access attribute of the primary
data volume is Read Only.
586906505
WSpecify another mirror ID.The specified mirror ID is already used
in the restore journal.
Specify another mirror ID.
586916505
WCheck the status of the master journal.The specified master journal cannot be
used for Delta resync, because it is
registered in the extended consistency
group (EXCTG).
586926505
WCheck the status of the restore journal.The specified restore journal cannot be
used for Delta resync, because it is
registered in the extended consistency
group (EXCTG).
586936505
WCheck the status of the secondary data
volume, or the status of the connected
communication line. When no
abnormality is found in the status of the
secondary data volume or the
communication line, please contact HP
Technical Support.
The Delta resync operation failed. Check
the status of the secondary data volume,
or the status of the connected
communication line.
586946505
WDelete the journal registered in the
extended consistency group (EXCTG),
then retry the operation with another
command device.
No more journals can be allocated to
the specified command device.
Delete the journals registered in the
extended consistency group (EXCTG),
then retry the operation with another
command device.
586956505
WCheck the I/O suppression mode of the
specified volume.
The specified volume cannot be used as
a journal volume because the volume is
an external volume to which the I/O
suppression mode is enabled.
586966505
202 Message (part code group 6nnn)