Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the attribute of the journals in the
specified extended consistency group
(EXCTG).
Journals cannot be added to the
specified extended consistency group
(EXCTG), because different journal
attributes coexist in the EXCTG.
586286505
WIf this problem persists please contact HP
Technical Support.
The specified operation failed because
of a temporary path failure. Retry the
operation. If this problem persists, please
contact HP Technical Support.
586296505
WConfirm whether the specified volume is
set by Cache Residency or Cache
Residency Z.
The specified volume cannot be used as
a journal volume because the volume is
set by Cache Residency or Cache
Residency Z.
586416505
WCheck the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
or the Continuous Access Journal Z
function supports the Delta resync
function.
The operation failed because the
Continuous Access Journal or the
Continuous Access Journal Z function of
the secondary storage system does not
support the Delta resync function.
586836505
WCheck the status of the primary data
volume in the Continuous Access
Synchronous window or the Continuous
Access Synchronous Z window.
The operation to change the status to the
status ready for Delta resync failed.
The specified primary data volume
should meet the following requirements.
• The specified volume is a secondary
data volume for Continuous Access
Synchronous, External Storage Access
Manager, or Continuous Access
Synchronous Z.
• The pair status of Continuous Access
Synchronous, External Storage Access
Manager, or Continuous Access
Synchronous Z is PAIR or Duplex.
586846505
WCheck the following of the specified
primary data volume.
• The volume is an M-VOL of a
synchronous pair or an External
Storage Access Manager pair, and
the pair status is in PAIR or Duplex
when it is referenced from the
Continuous Access Synchronous
window, the Continuous Access
Synchronous Z window, the RAID
Manager, or the Business Continuity
Manager.
• The volume is an R-VOL of a
synchronous pair or an External
Storage Access Manager pair, and
the pair status is in SSWS or
Swapping when it is referenced from
the RAID Manager or Business
Continuity Manager.
Delta resync operation failed because
the specified primary data volume was
not a data volume of Continuous Access
Synchronous, External Storage Access
Manager, or Continuous Access
Synchronous Z, or the pair status of the
primary data volume was invalid.
586856505
WCheck the attribute of the journal of the
remote storage system.
The specified operation failed, because
the attribute of the journal of the remote
storage system was not "restore."
586866505
Part code 6505 201