Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WRetry the operation after the microcode
exchange completes.
The specified operation failed because
the microcode exchange was in progress
on the subsystem in the extended
consistency group (EXCTG).
586116505
WWait a while, then retry the operation.The previously executed update
processing of the extended consistency
group (EXCTG) has not completed.
Please wait for a while, and then retry
the operation.
586126505
WCheck whether the specified CU number
and the LDEV number indicate a
command device.
The command device is specified
incorrectly.
586136505
WCheck if the specified journal is
registered.
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified journal is not
registered.
586146505
WCheck the mirror ID of the specified
journal.
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified mirror ID is not
registered in the specified journal.
586156505
WCheck the state of the journal in the
storage system where the specified
journal belongs to, or the installation
status of the program product.
The specified journal cannot be added
to extended consistency group (EXCTG).
586166505
WCheck the attributes of the specified
extended consistency group (EXCTG)
and the journal.
Journals cannot be added to the
extended consistency group (EXCTG),
because the attributes of the EXCTG and
the journal are different.
586176505
WCheck the timer type of the specified
journal.
Journals cannot be added to the
extended consistency group (EXCTG),
because the timer type of the specified
journal is not "System."
586186505
WWait a while, refresh the window, then
retry the operation.
The status of the extended consistency
group (EXCTG) is changing. Wait for a
while, refresh the window, and then retry
the operation.
586206505
WCheck the attribute of the specified
journal.
Journals cannot be added to the
extended consistency group (EXCTG),
because the attribute of the specified
journal is invalid.
586216505
WCheck if the specified command device
exists in the device of specified serial
number.
Journals cannot be added to the
extended consistency group (EXCTG),
because the combination of the serial
number and the command device is
invalid.
586246505
WCheck if the specified journal is being
used by other program product you are
using.
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified journals are being
used by another program product.
586256505
WCheck the status of the command device.The specified operation failed because
the command device was not registered
or has been blocked.
586276505
200 Message (part code group 6nnn)