Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WThe specified master journal group runs
on the 2DC configuration in which the
Continuous Access Synchronous or
External Storage Access Manager
cooperates.
Delete the Continuous Access
Synchronous or External Storage Access
Manager pair, and retry the operation,
or specify the volume that is not used by
the Continuous Access Synchronous or
External Storage Access Manager.
The Paircreate operation failed because
the specified primary data volume was
used by Continuous Access Synchronous
or External Storage Access Manager.
687836505
WThe master journal group of the specified
primary data volume runs on the 2DC
configuration in which the Continuous
Access Synchronous or External Storage
Access Manager cooperates.
Delete the Continuous Access
Synchronous or External Storage Access
Manager pair volume or suspend it.
The Pairresync operation failed because
the specified primary data volume was
one of the following.
The volume was not used by
Continuous Access Synchronous or
External Storage Access Manager.
The volume was used by Continuous
Access Synchronous or External
Storage Access Manager, but the pair
status was not PSUS or PSUE.
687846505
WCheck the status of the specified M-VOL
from the host or the SVP.
The M-VOL cannot be used because
M-VOL is a volume of FICON(R) Data
Migration.
688046505
WCheck the status of the specified R-VOL
from the host or the SVP.
The R-VOL cannot be used because
R-VOL is a volume of FICON(R) Data
Migration or Data Migration.
688056505
WSpecify a volume that is not used by
FICON(R) Data Migration.
The specified volume cannot be used as
a journal volume because it is used by
FICON(R) Data Migration.
688116505
WCheck each capacity of the primary data
volume and the secondary data volume
after the capacity change of secondary
data volume ends. Plan a combination
of volumes for pair creating.
A pair could not be created because the
specified secondary data volume was a
Thin Provisioning volume whose capacity
was being changed.
688126505
WCheck each capacity of the primary data
volume and the secondary data volume
after the capacity change of primary
data volume ends. Plan a combination
of volumes for pair creating.
A pair could not be created because the
specified primary data volume was a
Thin Provisioning volume whose capacity
was being changed.
688136505
WThe specified volume runs on the 2DC
configuration in which the Continuous
Access Synchronous or External Storage
Access Manager cooperates.
Release the pair of Continuous Access
Synchronous or External Storage Access
Manager, then retry the operation.
The pair cannot be released because the
specified volume is used as the pair
volume of Continuous Access
Synchronous or External Storage Access
Manager.
688156505
WRetry the operation after the completion
of discarding zero data on the specified
volume.
The operation failed, because the
specified secondary data volume was a
volume of Thin Provisioning whose zero
data was being discarded.
688426505
212 Message (part code group 6nnn)

Table of Contents

Other manuals for HP StorageWorks P9000