Loading...
Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WRetry the operation after the completion
of discarding zero data on the specified
volume.
The operation failed, because the
specified primary data volume was a
volume of Thin Provisioning whose zero
data was being discarded.
688436505
WWait until the initializing process is
completed, then retry the operation.
The operation failed, because the
specified primary data volume was
being initialized by Business Copy or
Business Copy Z.
688486505
WWait until the initializing process is
completed, then retry the operation.
The operation failed, because the
specified secondary data volume was
being initialized by Business Copy or
Business Copy Z.
688496505
WSpecify “Mirror for the [Range], then
retry the operation.
The operation failed, because the
consistency (CT) group of specified data
volume was being shared with multiple
primary and secondary storage systems,
and “LU” was specified for the [Range].
688506505
WSpecify another CT group, then retry the
operation.
The operation failed, because the
specified consistency (CT) group was
shared with multiple primary and
secondary storage systems.
688516505
WCheck whether the specified CT group
or the secondary data volume was
shared with multiple primary and
secondary storage systems or not.
The operation failed, because the
specified consistency (CT) group or the
secondary data volume was being
shared with multiple primary and
secondary storage systems. This CT
group or the secondary data volume
cannot be used for Delta resync.
688526505
WSpecify another journal, then retry the
operation.
The operation failed, because the
specified journal was shared with
multiple primary and secondary storage
systems.
688536505
WCheck if a remote command device is
assigned to the specified mirror.
The operation failed, because a remote
command device has already been
assigned to the specified mirror.
688576505
WCheck the status of the specified mirror.The operation failed, because the
specified mirror was invalid.
688586505
ECheck the status of the specified remote
command device.
The operation failed, because the
specified remote command device was
blocked.
688596505
WCheck if the serial number of the external
volume that is used as a remote
command device matches the one of the
storage system connected to the mirror.
The operation failed, because the serial
numbers between the remote command
device and the mirror did not match.
688606505
WCheck the status of the specified journal.The operation failed, because the
specified journal was not in the
configuration of 3DC cascade or 3DC
multi target.
688616505
WSpecify another remote command
device, then retry the operation.
The specified remote command device
cannot be assigned to a mirror any
further.
688626505
Part code 6505 213