The path status that requires
the action appears in the
Alternate Path list on the Path
Setting window (see Setting
alternate paths for external
LUs” on page 74).
The following rows describe path status values displayed in the Alternate Path list
and corrective actions for each status value. See ”Notes on connecting external
disk arrays” on page 101 for notes on connection settings and examples of
recovery procedures, and then take the corrective action.
Unknown Status: The path status is unknown.
Corrective action: The path status cannot be
identified. Contact your HP account support
representative.
Blockade Status: The external port is blocked.
Corrective action: The external port is blocked
because of the microprogram or package
replacement or some other factor. Check the local
disk array’s status. If you cannot restore the path,
contact your HP account support representative.
External device setting
changed
Status: The configuration of the external disk array
changed. For example, the path definition was
deleted, or the external disk array itself was
replaced by another device.
Corrective action: The port of the external disk array
is recognized. See the internal disk array’s
documentation, and check if the operation that
changes the mapped device’s setting information
has not been performed.
LDEV size reduced
Status: The volume capacity setting of the external
disk array changed (was reduced).
Corrective action: Check the volume capacity of
the external disk array’s LU. Execute the Delete LU
operation, and execute the Add LU operation.
Not ready Status: The reply from the external disk array was
NOTREADY. The external disk array’s drive is
spinning up, or the external disk array’s device is
being formatted.
Corrective action: The path cannot be used to access
the external disk array. Check the external disk
array’s status. If you cannot restore the path, contact
your HP account support representative.
Illegal request Status: The reply from the external disk array was
ILLEGAL REQUEST. The command cannot be
executed to the external disk array’s device. Data
protection might be set on the external disk array’s
device.
Corrective action: The external disk array’s port is
recognized. Check the external disk array’s setting.
If you cannot restore the path, contact your
HP account support representative.
Table 11 General External Storage XP troubleshooting (continued)
Error Corrective action

Table of Contents

Other manuals for HP StorageWorks

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks and is the answer not in the manual?

HP StorageWorks Specifications

General IconGeneral
BrandHP
ModelStorageWorks
CategoryStorage
LanguageEnglish

Related product manuals