For more information on cable, power, environmental, compliance, and general specifications, see the HPE Compute Transceiver andHPE Compute Transceiver and
Cable Hardware MatrixCable Hardware Matrix.
Environmental specificationsEnvironmental specifications
SpecificationSpecification ValueValue
Temperature rangeTemperature range
Operating 10°C to 35°C (50°F to 95°F)
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)Relative humidity (noncondensing)
Operating 8% to 90%. 28°C (82.4°F), maximum wet bulb temperature
Nonoperating 5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
AltitudeAltitude
Operating 3050 m (10,000 ft). This value may be limited by the type and
number of options installed. Maximum allowable altitude change
rate is 457 m/min (1500 ft/min).
Non-operating 9144 m (30,000 ft). Maximum allowable altitude change is 457
m/min (1500 ft/min).
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1,000 ft) to 3,050 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.