Caution: All bays must be populatedCaution: All bays must be populated
CAUTION: CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated
with either a component or a blank.
Removing and replacing an SFF hot-plug driveRemoving and replacing an SFF hot-plug drive
CAUTION: CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated
with either a component or a blank.
ProcedureProcedure
1. Back up all server data on the drive.
2. Remove the front bezel .
3. Determine the status of the drive from the drive LED definitions .
4. Remove the drive.
To replace the component, reverse the removal procedure.
Removing and replacing media devicesRemoving and replacing media devices
Removing and replacing a SAS LTO tape driveRemoving and replacing a SAS LTO tape drive
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
HPE ProLiant ML30 Gen10 Server Maintenance and Service Guide 44