Removing and replacing the system fanRemoving and replacing the system fan
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
5. Remove the front bezel .
6. Remove the access panel .
7. If installed, remove the air baffle .
8. Remove the system fan:
a. Disconnect the fan power cable.
b. Remove the screws securing the fan cage.
c. Remove the system fan.
To replace the component, reverse the removal procedure.
Removing and replacing the energy packRemoving and replacing the energy pack