Type Paramet
er
Description Example
Password Password for logging in to the iBMC
WebUI.
NOTE
The default username for logging in to the
iBMC WebUI of V2 & V3 servers is root, and
the default password is Huawei12#$.
The default user name for logging in to the
iBMC WebUI of V5 servers/Atlas 800 AI
inference servers (model 3010)/Atlas 800 AI
training servers (model 9010) is
Administrator, and the default password is
Admin@9000.
Huawei12#$
Procedure 1 (For iBMC V549 and Earlier)
This section uses a PC running Windows 7 and Internet Explorer 8.0 as an
example.
Step 1 Connect the local PC to the iBMC management network port on the server by
using a crossover cable or twisted pair cable.
Figure 8-21 shows the network diagram.
Figure 8-21 Network diagram
Step 2 Open Internet Explorer on the local PC.
Step 3 In the address box, enter the IP address of the server iBMC management network
port (for example, https://192.168.2.100) and press Enter.
The iBMC login page is displayed, as shown in Figure 8-22.
NO TE
If the message "There is a problem with this website's security certicate" is displayed,
click Continue to this website (not recommended).
If the Security Alert dialog box indicating a certicate error is displayed, click Yes.
Huawei Servers