Page #90 background imageLoading...
Page #90 background image
Tools and Materials
ESD wrist strap
ESD bag
Labels
Procedure
Step 1 Perform a pre-replacement check.
Check whether there is a redundant fan module and whether the Running/Alarm
indicator of the fan module is steady green, as shown in Figure 6-77. For details
about the indicators on
dierent components, see Running/Alarm Indicators on
a 3 U Controller Enclosure.
Figure 6-77 Running/Alarm indicator on a fan module
NO TICE
You can perform replacement only when a redundant fan module exists and the
redundant fan module is working properly.
Step 2 Wear an ESD wrist strap.
Step 3 Remove a fan module, as shown in Figure 6-78.
1. Press the latch on the panel to open the panel.
2. Press the latches on the fan module to pull out the fan module.
OceanStor V5 Series
Parts Replacement 6 Replacing CRUs
Issue 15 (2019-12-30) Copyright © Huawei Technologies Co., Ltd. 81

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei OceanStor V5 Series and is the answer not in the manual?

Huawei OceanStor V5 Series Specifications

General IconGeneral
Drive TypesSSD, SAS, NL-SAS
Data ReductionDeduplication, Compression
SeriesOceanStor V5
CategoryStorage
Supported ProtocolsFC, iSCSI, NFS, CIFS, HTTP
RAID Levels0, 1, 3, 5, 6, 10, 50
Data Protectionremote replication
Operating System CompatibilityWindows, Linux, VMware, AIX, HP-UX
High AvailabilityRedundant components, controller failover
Power SupplyRedundant power supplies
CoolingRedundant fans

Related product manuals