50 MAXPRO200 Instruction Manual 807700 Revision 1
Installation
Note: The plasma gas and coolant return hose connectors mentioned below are push-to-connect fittings.
To make a connection, push the hose fitting into the appropriate connector until it stops, 12 mm (0.472 in).
To disconnect a fitting, push the connector-collar and hose toward the fitting, hold the collar in place and pull the
hose away from the fitting.
3. Connect the coolant return hose (red).
4. Connect the plasma gas hose (black).
Connector-collar