SPECIFICATIONS
powermax
65/85
Operator Manual 1-9
2
Equipment complies with IEC 61000-3-12 provided that the short-circuit power S
sc
is greater
than or equal to 2035 KVA at the interface point between the user’s supply and the public
system. It is the responsibility of the installer or user of the equipment to ensure, by consultation
with the distribution network operator if necessary, that the equipment is connected only to a
supply with a short-circuit power S
sc
greater than or equal to 2035 KVA.
3
Equipment complies with IEC 61000-3-11 provided that the supply impedance, Zmax, is 0.201
or less. It is the responsibility of the installer or user of the equipment to ensure, by consultation
with the distribution network operator if necessary, that the equipment is connected only to a
supply with a impedance of 0.201 or less.
4
WARNING: This Class A equipment is not intended for use in residential locations where the
electrical power is provided by the public low-voltage supply system. There may be potential
difficulties in ensuring electromagnetic compatibility in those locations, due to conducted as well
as radiated disturbances.
1
Defined as a plot of output voltage versus output current.

Table of Contents

Other manuals for Hypertherm Powermax 65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 65 and is the answer not in the manual?

Hypertherm Powermax 65 Specifications

General IconGeneral
Open Circuit Voltage (OCV)300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Maximum Cut Capacity (Mild Steel)1" (25 mm)
Input Voltage200-600 V, 1/3-PH, 50/60 Hz
Output Current20 – 65 A
Duty Cycle50% @ 65 A
Recommended Gas Inlet Flow Rate/Pressure6.7 scfm @ 85 psi
Torch Lead Length25 ft (7.6 m)
Maximum Cut Capacity (Aluminum)5/8" (16 mm)
Severance Cut Capacity (Mild Steel)1-1/4" (32 mm)
Maximum Severance Thickness1-1/4 in (32 mm)
Gas TypeAir/Nitrogen
Torch OptionsHand Torch, Mechanized Torch