PARTS
6-8
powermax
65/85
Operator Manual
Part number Description
Drag cutting
220818 Shield
220854 Retaining cap
220941 45 A Nozzle
220819 65 A Nozzle
220816 85 A Nozzle
220842 Electrode
220857 Swirl ring
Gouging
220798 65 A/85 A shield
220854 Retaining cap
220797 65 A/85 A nozzle
220842 Electrode
220857 Swirl ring
FineCut 45 A
220931 Deflector
220854 Retaining cap
220930 Nozzle
220842 Electrode
220947 Swirl ring
Hand torch consumables

Table of Contents

Other manuals for Hypertherm Powermax 65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 65 and is the answer not in the manual?

Hypertherm Powermax 65 Specifications

General IconGeneral
Open Circuit Voltage (OCV)300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Maximum Cut Capacity (Mild Steel)1" (25 mm)
Input Voltage200-600 V, 1/3-PH, 50/60 Hz
Output Current20 – 65 A
Duty Cycle50% @ 65 A
Recommended Gas Inlet Flow Rate/Pressure6.7 scfm @ 85 psi
Torch Lead Length25 ft (7.6 m)
Maximum Cut Capacity (Aluminum)5/8" (16 mm)
Severance Cut Capacity (Mild Steel)1-1/4" (32 mm)
Maximum Severance Thickness1-1/4 in (32 mm)
Gas TypeAir/Nitrogen
Torch OptionsHand Torch, Mechanized Torch