TORCH SETUP
3-30
powermax
65/85
Operator Manual
85A Shielded Air flow rate - slpm/scfh
Stainless Steel
Hot 190 / 400
Cold 235 / 500
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
3
1.5
3.8 250
0.1 7500 122 11500 115
4 0.2 6100 122 9400 117
6
0.5
3700 122 5700 121
8 2450 124 3800 123
10 1550 127 2400 124
12
4.5 300
0.7 1100 131 1750 125
16 1.0 700 135 950 131
20
Edge Start
480 138 700 132
25 300 143 480 135
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
10GA
0.06
0.15 250
0.2
275 122 420 116
3/16 in 200 122 300 119
1/4 in
0.5
130 122 205 122
3/8 in 65 126 100 124
1/2 in
0.18 300
36 132 60 125
5/8 in 1.0 28 135 38 131
3/4 in
Edge Start
20 137 30 132
7/8 in 16 140 24 134
1 in 11 143 18 135