TORCH SETUP
powermax
65/85
Operator Manual 3-35
65A Shielded Air flow rate - slpm/scfh
Aluminum
Hot 160 / 340
Cold 220 / 470
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
2
1.5
3.8 250
0.1 8800 121 12800 122
3 0.2 7400 124 11000 123
4
0.5
6000 126 9150 124
6 3200 130 5500 127
8
0.7
1950 133 3450 129
10
4.5 300
1200 136 2050 130
12 1.2 1000 138 1650 132
16
Edge Start
650 143 1000 134
20 380 147 700 137
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
1/16 in
0.06
0.15 250
0.1
365 121 535 121
1/8 in 280 124 420 123
1/4 in 0.5 105 131 190 127
3/8 in
0.18 300
0.7 50 135 85 130
1/2 in 1.2 35 139 60 133
5/8 in
Edge Start
26 143 40 134
3/4 in 16 146 30 136

Table of Contents

Other manuals for Hypertherm Powermax 65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 65 and is the answer not in the manual?

Hypertherm Powermax 65 Specifications

General IconGeneral
Open Circuit Voltage (OCV)300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Maximum Cut Capacity (Mild Steel)1" (25 mm)
Input Voltage200-600 V, 1/3-PH, 50/60 Hz
Output Current20 – 65 A
Duty Cycle50% @ 65 A
Recommended Gas Inlet Flow Rate/Pressure6.7 scfm @ 85 psi
Torch Lead Length25 ft (7.6 m)
Maximum Cut Capacity (Aluminum)5/8" (16 mm)
Severance Cut Capacity (Mild Steel)1-1/4" (32 mm)
Maximum Severance Thickness1-1/4 in (32 mm)
Gas TypeAir/Nitrogen
Torch OptionsHand Torch, Mechanized Torch