TORCH SETUP
3-38
powermax
65/85
Operator Manual
45A Shielded Air flow rate - slpm/scfh
Stainless Steel
Hot 147 / 310
Cold 210/ 450
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
0.5
1.5 3.8 250
0.0
9000 130 12700 130
1 9000 130 12700 130
1.5 0.1 9000 130 12700 130
2 0.3 6000 132 10800 130
3
0.4
3100 132 5550 131
4 2000 134 3250 132
6 0.5 900 140 1250 138
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
26GA
0.06 0.15 250
0.0
350 130 500 130
22GA 350 130 500 130
18GA
0.1
350 130 500 130
16GA 350 130 500 130
14GA 0.2 250 132 450 130
12GA
0.4
140 132 258 130
10GA 100 133 168 135
3/16 in 0.5 52 135 73 133
1/4 in 0.6 30 141 44 140