Diagnostics and Troubleshooting
8
286 810060 Instruction Manual XPR170
707
Error
No sensor P2-TCC The P2 pressure sensor in
the torch connect console is
not detected.
Refer to Pressure transducer diagnostic codes
(706 – 715) on page 327.
Ramp down Set process;
remote on-off
708
Error
No sensor P3-TCC The P3 pressure sensor in
the torch connect console is
not detected.
Ramp down Set process;
remote on-off
709
Error
No sensor P4-TCC The P4 pressure sensor in
the torch connect console is
not detected.
Ramp down Set process;
remote on-off
710
Error
No sensor P5-TCC The P5 pressure sensor in
the torch connect console is
not detected.
Ramp down Set process;
remote on-off
711
Error
No sensor P14-
TCC
The P14 pressure sensor in
the torch connect console is
not detected.
Ramp down Set process;
remote on-off
712
Error
(VWI and OptiMix
only)
No sensor
P6-GCC
The P6 pressure sensor in
the gas connect console is
not detected.
Ramp down Set process;
remote on-off
713
Error
(VWI and OptiMix
only)
No sensor
P7-GCC
The P7 pressure sensor in
the gas connect console is
not detected.
Ramp down Set process;
remote on-off
714
Error
(VWI and OptiMix
only)
No sensor
P8-GCC
The P8 pressure sensor in
the gas connect console is
not detected.
Ramp down Set process;
remote on-off
715
Error
No sensor
P9-GCC
The P9 pressure sensor in
the gas connect console is
not detected.
Ramp down Set process;
remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action