9. Maintenance and Inspection
9.6 Internal Cleaning
Wipe off dirt with a soft cloth.
Do not use strong compressed air on the actuator as this may force dust into the crevices.
Do not use petroleum-based solvent, neutral detergent or alcohol.
Caution: Do not use flushing oil, molybdenum grease or anti-rust lubricant.
When grease is soiled with a large amount of foreign substances, wipe off the dirty grease and
then apply new grease.
9.7 Grease Supply
9.7.1 Applicable Grease
[Other than Cleanroom Specification]
1) What Grease to Use on the Guides
The following grease is used when we ship the unit.
Idemitsu Kosan Daphne Eponex Grease No.2
Other companies also sell a grease similar to this. If ordering from another maker, give the name of this
product and request something comparable. Comparable products include the following:
Showa Shell Oil Albania Grease S2
Mobil Oil UNIREX N2
(2) What Grease to Use on the Ball Screw
The following grease is used when we ship the unit.
This grease offers excellent properties such as low heat generation, and is suitable for lubricating ball
screws.
Kyodo Yushi Multemp LRL3
Caution: Never use any fluorine-based grease. It will cause a chemical reaction when mixed with a
lithium-based grease and may cause damage to the actuator.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI ROBO Cylinder RCP2 Series and is the answer not in the manual?

IAI ROBO Cylinder RCP2 Series Specifications

General IconGeneral
BrandIAI
ModelROBO Cylinder RCP2 Series
CategoryController
LanguageEnglish

Related product manuals