3995 Model C60
Dimensions
Height 457 mm 18.0 in.
Width 216 mm 8.5 in.
Depth 737 mm 29.0 in.
Weight
Minimum (w/o
cartridges)
28.0 kg 61 lbs
Maximum (with 20
cartridges)
34.1 kg 75 lbs
Typical weight of
cartridge
0.32 kg 0.7 lbs
Electrical
Power source loading 0.14
(typical in kVA) @
120 V ac
Voltage range (V ac) 100 to 127 or 200 to 240
Frequency (hertz) 50 or 60
Thermal output
(typical)
275 Btu/hr
Power requirements
(typical)
80 watts
Maximum altitude 2135 m (7000 ft.)
Temperature
Requirements
Operating
10 to 38°C
(50 to 100.4°F)
Non-Operating
10 to 52°C
(50 to 125.6°F)
Humidity
Requirements
Operating Non-Operating
(Noncondensing) 8 to 80% 8 to 80%
Wet Bulb 25.8°C(78.4°F) 27°C(80°F)
Noise Emissions* Operating Idle
L
WAd
6 bels 5.5 bels
L
pAm
N/A N/A
<L
pA
>
m
N/A N/A
Impulsive noise Yes Yes
Prominent discrete
tones
No No
Clearances Front Back Left Right
Install/Air flow leave open for
operator panel
76 mm (3 in) 76 mm (3 in) 76 mm (3 in)
Service Install so that it can be moved to an area providing 760 mm (30 in) on each side.
* See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
Chapter 6. Physical Characteristics of the 3000 Series 261