7319 Models 100 and 110 Fibre Channel Switches
Dimensions
Height 86 mm 3.39 in.
Width 483 mm 19.00 in.
Depth 495 mm 19.50 in.
Weight
Maximum 12.2 kg 27 lbs.
Electrical
Power source loading 0.18
(typical in kVA)
Voltage range (V ac) 100 to 125 or 200 to 240 (autoranging)
Frequency (hertz) 50 or 60
Thermal output
(typical)
570 Btu/hr
Power requirements
(typical)
170 watts
Power factor 0.98
Maximum altitude 2135 m (7000 ft.)
Temperature
Requirements
Operating
0 to 40°C
(32 to 104°F)
Non-Operating
0 to 50°C
(32 to 125°F)
Humidity
Requirements
Operating Non-Operating
(Noncondensing) 0 to 90% 0 to 90%
Wet Bulb 27°C (80°F) 27°C (80°F)
Noise Emissions* Operating Idle
L
WAd
4.9 bels 4.9 bels
L
pAm
N/A N/A
Impulsive or
prominent discrete
tones
No No
1. * See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.