7131 Model 405 SSA Multi-Storage Tower
Dimensions
Height 407 mm 16.0 in.
Width (at pedestal) 197 mm 7.8 in.
Depth 483 mm 19.0 in.
Weight
Minimum 15.4 kg 34 lbs.
Maximum 18.0 kg 40 lbs.
Electrical
Power source loading 0.39
(typical in kVA)
Voltage range (V ac) 100 to 125 or 200 to
240 (selectable)
Frequency (hertz) 50 or 60
Thermal output (max) 785 Btu/hr
Power requirements
(max)
230 watts
Power factor 0.5
Maximum altitude 2135 m (7000 ft.)
Temperature
Requirements
Operating
16 to 32°C
(60 to 90°F)
Non-Operating
10 to 43°C
(50 to 110°F)
Humidity
Requirements
Operating Non-Operating
(Noncondensing) 20 to 80% 20 to 80%
Wet Bulb 23°C (73°F) 27°C (80°F)
Noise Emissions¹ Operating Idle
L
WAd
(5 devices) 6.0 bels 5.6 bels
L
pAm
N/A N/A
<L
pA
>
m
50 dBA 46 dBA
Impulsive or
prominent discrete
tones
No No
Clearances Front Back Left Right
Install/Air Flow² 152 mm(6 in) 152 mm(6 in) 25 mm(1 in) 25 mm(1 in)
Service 152 mm(6 in) N/A N/A 25mm(1in)
Footprint
2
Width
250mm(9.8 in)
Depth
790mm(31 in)
1. See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
2. The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
268 Site and Hardware Planning Information