Cleaning The Printhead, Platen Roller And Media Sensors
85
1. Rotate the deck lock lever clockwise to open the pivoting deck and
remove any media and ribbon (if loaded) to gain access to the printhead
assembly heating element area.
2. Gently rub the felt tip of the cleaning pen or a cotton swab with Isopropyl
alcohol across the printhead heating elements (light brown area).
3. Allow the printhead to dry for one minute before reloading the media and
ribbon.
4. Clean the platen roller.
5. Clean the upper media sensor with a soft cloth.
6. Clean the lower media sensor by vacuuming or blowing air across the
lens cover.