EasyManuals Logo

IBM Storwize V7000 Unified Series User Manual

IBM Storwize V7000 Unified Series
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
1. Click Monitoring > Events and ensure that you are filtering the event log to
display Recommended actions.
The list might contain any number of errors that must be repaired. If there is
more than one error on the list, the error at the top of the list has the highest
priority and must always be fixed first. If you do not fix the higher priority
errors first, you might not be able to fix the lower priority errors.
2. Select the error at the top of the list or select the Next recommended action.
3. Click Run Fix Procedure.
The panel displays the error code and provides a description of the condition.
4. Click Next to go forward or Cancel to return to the previous panel.
5. One or more panels might be displayed with instructions for you to replace
parts or perform other repair activity. If you are not able to complete the
actions at this time, click Cancel until you return to the previous panel. Click
Cancel until you are returned to the Next Recommended Actions panel. When
you return to the fix procedures, the repair can be restarted from step 1. When
the actions that you are instructed to perform are complete, click OK. When the
last repair action is completed, the procedures might attempt to restore failed
devices to the system.
6. After you complete the fix, you see the statement Click OK to mark the error
as fixed. Click OK. This action marks the error as fixed in the event log and
prevents this instance of the error from being listed again.
7. When you see the statement The repair has been completed., click Exit.If
other errors must be fixed, those errors are displayed and the fix procedures
continue.
8. If no errors remain, you are shown the following statement: There are no
unfixed errors in the event log.
50 Storwize V7000 Unified: Problem Determination Guide Version
|
|
|
|
|
|

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified Series and is the answer not in the manual?

IBM Storwize V7000 Unified Series Specifications

General IconGeneral
Form Factor2U
Maximum Drives504
RAID Levels0, 1, 5, 6, 10
File ProtocolsNFS, CIFS/SMB, FTP, HTTP, HTTPS
Drive TypesSAS, SSD
Maximum Cache64 GB
Host Interface8 Gb FC, 16 Gb FC, 10 Gb iSCSI, 1 Gb iSCSI
File System SupportGPFS
Data ServicesThin provisioning, Easy Tier, FlashCopy, Remote Mirroring
Management InterfaceCLI
ScalabilityScale-out
Operating System SupportWindows, Linux, AIX, VMware
Power SupplyRedundant power supplies
Maximum CapacityUp to 4PB