40
6
SET MODE
6
Initial set mode
Initial set mode operation is used for programming in-
frequently changed values, conditions or functions.
DD
Entering set mode
q Turn the transceiver power OFF, if the transceiver is
powered ON.
w While pushing [OK
], push [I/O] to turn the trans-
ceiver power ON to enter initial set mode.
•S
etting menu which are 7 groups appears.
e Push [
]/[
] to select the desired group.
r Push [OK
] to edit the selected setting group.
(Eg. select ‘GENERAL’)
tPush [
]/[
] to select the desired item of the group.
(Eg. select ‘COMP’)
y Push [
CLR]/[OK
] to set the values or condi-
tions for the selected item.
u After all setting is nished, turn the power OFF and
ON again to exit the Initial set mode.
[ CLR]/[OK ]
[]/[]
[I/O] [OK ]
GENERAL----
--DISP-TYPE--RX-TX
è-CLOCK------12:00
--COMMENT----ON
--COMP-------ç-ON-å
é-SELCALL----
--ALE--------
è-SCAN-------
--GENERAL----å
--I/O--------
SET-MODE
--CH-LIST- å
è-SCAN
--ID-LIST
--I/O
é-SELCALL--å
--ALE
--GENERAL
Push or