12
ifm System Manual ecomatmobile BasicDisplay (CR0451) V01
System description PLC configuration
IMPORTANT: the following files must also be loaded:
the internal libraries (created in IEC 1131) required for the project,
the configuration files (*.CFG)
and the target files (*.TRG).
Important: the following devices must have at least the here listed targets:
Device Target at least version ...
BasicController: CR040n V01
BasicDisplay: CR0451 V01
CabinetController: CR030n V05
ClassicController: CR0020, CR0505 V05
ClassicController: CR0032 V02
ExtendedController: CR0200 V05
ExtendedController: CR0232 V01
SafetyController: CR7020, CR7021, CR7200, CR7201, CR7505, CR7506 V05
SafetyController: CR7032, CR7232 V01
SafetyController: CR7nnn V05
WARNING
The user is responsible for the reliable function of the application programs he designed. If necessary,
he must additionally carry out an approval test by corresponding supervisory and test organisations
according to the national regulations.
3.3 PLC configuration
1797
The control system ecomatmobile is a device concept for series use. This means that the devices
can be configured in an optimum manner for the applications. If necessary, special functions and
hardware solutions can be implemented. In addition, the current version of the ecomatmobile
software can be downloaded from our website at: www.ifm.com
.
Setup the target (→ page 18
)
Before using the devices it must be checked whether certain functions, hardware options, inputs and
outputs described in the documentation are available in the hardware.