102 A20733 B0
Troubleshooting
Anomalies displayed Solutions
8- Additive tank level low
or
Additive tank empty
or
Solvent fault
8a- Add additive to the corresponding tank (max. 1/2 tank)
8b- Check that the additive addition electrovalve operates
correctly (
fi). Check the viscometer
circuit.
8c- If the fault persists, contact Imaje technical support.
9- V.24 fault. 9a- Contact Imaje technical support.
10- Fault: °C 10a- The ambient temperature in the room where the printer is too
high, causing the temperature in the electronic compartment
to exceed 70°C. Modify the installation.
10b- The main board is faulty. Contact Imaje technical support.
11- Viscometer fault 11a- Check that the viscometer electrovalve operates correctly by
monitoring viscometer level variations (
fi).
11b- If the fault persists, contact Imaje technical support.
12- No message to print 12a- The printer is linked to an external controller and has not
received a message to print. Check message transmission
and content and check the link.
13- Unknown CG number 13a- The printer is linked to an external controller and the CG
(character generator) number received is incorrect. Check
the CG numbers in the printer and ensure that the data sent
by the controller corresponds.
IMPORTANT: the CG numbers are different on each line.
13b- If this fault occurs after resetting the main board, the
message library must also be deleted (
fs).
13c- The main board may be faulty. Contact Imaje technical
support.
14- Fan fault 14a- Check that the fan at the bottom of the console is correctly
connected and running. It must run continuously immediately
after the printer starts up.
14b- The main board is faulty. Contact Imaje technical support.