A20733 B0 61
TIME CODE
Role
This function is used to define the parameters of the time code.
Access
Display
S : 08:00 = time code start time
I : 00:01 = interval between each code change
01 : type of code to print
Modify using
d to move the cursor to "S", "I" or code type.
b+ numeric keys for "S" and "I".
btfor the type of code to print.
Choices
S = 00:00 to 23:59
I = 00:01 to 23:59
01 = numeric code from 01 to 24
A = alphabetic code from A to Z
A-O-I = alphabetic code from A to Z, excluding O and I.
Example:
Start time = 05:00
Interval = 8:00
Code = A
Thetimecodeprintedis:
from 05:00 to 12:59: A
from 13:00 to 20:59: B
from 21:00 to 04:59: C
etc.
M30
Function?...
s
Display the message
number by pressing
d or g then j d
S: 08: 00 I: 00: 01 01
Autodating