80 A20733 B0
Servicing
INK VISCOSITY CHECK
Role
This function displays the viscosity monitoring data.
The printer continually monitors and controls the ink viscosity to ensure
that the break-off point is correct.
Access
fid (3 times)
Display
Lhl: ++ Viscometer full
Lhl: - + Viscometer filling or emptying
Lhl: - - Viscometer empty
Only the electrovalve status can be modified manually to check that the
entire viscometer circuit is operating correctly.
E10
Function?...
Visco: PS:OC Lhl:++ Ft:31s → 29s 07add
Number of additive additions since start-up.
Viscometer filling time reference value.
Actual value of viscometer filling time. This
value must be less than or equal to the
reference value.
Viscometer high and low level.
Electrovalve opening and closing
Additive electrovalve.
Viscometer electrovalve
Viscometer level:
Nhb: ++
Low level: + reached by ink, - not reached by ink.
High level: + reached by ink, - not reached by ink.
Viscometer low level.
Viscometer high level