4.3 TECHNICAL DATA TABLE
VICTRIX TERA V2 24
PLUS EU
VICTRIX TERA V2 35
PLUS EU
Central heating nominal heat input kW 24,5 32,8
Minimum heat input kW 4,5 6,3
PoCentral heating nominal heat input with 20%H2NG gas kW 23,2 31,4
Minimum heat input with 20%H2NG gas kW 4,3 6,0
Central heating nominal heat output (useful) kW 24,0 32,0
Minimum heat output (useful) kW 4,3 6,1
*Eective thermal eciency 80/60 Nom./Min. % 97,8 / 96,6 97,7 / 96,8
*Eective thermal eciency 50/30 Nom./Min. % 106,5 / 107,6 104,8 / 105,6
*Eective thermal eciency 40/30 Nom./Min. % 108,0 / 108,4 106,6 / 107,1
Casing losses with burner On/O (80-60°C) % 0,36 / 0,10 0,29 / 0,10
Chimney losses with burner On/O (80-60°C) % 0,02 / 2,10 0,01 / 2,20
Eciency at 100% heat output (η100) ref. UNI EN 15502-1 % 97, 5 97,6
Eciency at partial heat load (η30) ref. UNI EN 15502-1 % 109,6 109,2
Central heating circuit max. operating pressure bar 3,0
Maximum heating temperature °C 90
Adjustable central heating temperature (min. operating eld) °C 20
Adjustable central heating temperature (max operating eld) °C 85
Appliance water content l 3,3 3,8
Head available with 1000 l/h ow rate kPa 24,4 31,6
Weight of full boiler kg 34,5 39,6
Weight of empty boiler kg 31,2 35,8
Electrical connection V/Hz 230 / 50
Nominal power absorption A 0,7 1,0
Installed electric power W 90 130
Equipment electrical system protection IP X5D
Ambient operating temperature range °C -5 ÷ 40
Ambient operating temperature range with antifreeze kit (optional) °C -15 ÷ 40
NO
X
class - 6
*Wei ghted NO
X
G20 mg/kWh 39 28
Weighted CO G20 mg/kWh 16 17
Wei ghted NO
X
G31 mg/kWh 33 31
Weighted CO G31 mg/kWh 16 21
Type of appliance -
B23 B23p B33 B53 B53p C13 C33 C43 C53 C63 C83
C93 C13X C33X C43X C53X C63X C83X C93X
C(10)3 C (12)3 C(10)3X C(12)3X
Market IE
Category II2H3P
* Eciencies and weighted NOx refer to the net caloric value.
e data relevant to domestic hot water performance refer to a dynamic inlet pressure of 2 bar and an inlet temperature of 15°C; the values
are measured directly at the appliance outlet considering that to obtain the data declared mixing with cold water is necessary.
For type C63 it is forbidden to install the appliance as it came out of the factory, in congurations that require shared ues in positive
pressure.
Congurations C
(10)
and C
(12)
are only permitted with original, approved ue system
e appliance is suitable for operation in a C
(10)
or C
(12)
system and only with the supply of methane gas (2H and 2E categories).