108
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
3.23 ASSEMBLY OF MANIFOLD GASKET ON CONDENSATION MODULE
e operations described below must be performed aer having removed the voltage from the
appliance.
Aer checking the integrity of the seals, proceed as follows if they need to be replaced:
Victrix Tera V2 24 Plus EU
1. Remove old seals.
2. Place the module gasket (1) radially on the edge of the condensation module ange (2).
3. Make sure that the gasket tab with number 4 printed on it is positioned in its seat on the module ange, identied by the number 4.
Every time the manifold is opened, the condition and integrity of the ceramic bres must be veried and re-
placed, if necessary. e manifold gasket, on the other hand, must be replaced every 2 years. Aer replacing the
external silicone gasket, it is mandatory to check the fume tightness.
1
2
77