51
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
1.23 CONCENTRIC KIT C
10
CONFIGURATION Ø 80/125
In the C
(10)
and C
(12)
installations, the appliance ue exhaust must be tted with a ue gas
non-return valve kit, supplied by Immergas as an optional, consisting of the valve itself with
instructions, specication and relative sticker with additional safety information (Fig.37).
1
34
C
10
35
Installation in "C
10
" conguration of an Immergas appliance (only
permitted with approved original ue, including the specic
non-return valve), makes it possible to intake combustion air di-
rectly from the sha where the ue gas exhaust is present in the
collective ue.
e connection to the intake sha is possible with a Ø
125 ue.
e collective ue coupling for the exhaust is possible
with female Ø 80 ue with gasket (Fig. 37).