InHand VG710 InVehicle Gateway User Manual
5
Telnet is disabled.
SSH is disabled.
Access from the cellular network is allowed only over HTTPS.
7
User name and
password
adm/123456 (super administrator)
8
Power
management
shutdown-delay 30: The power-off delay is 30s.
standby-mode 1: The power-off function is enabled.
standby-check-interval 20 indicates the power check interval in
standby mode.
standby-voltage 90: The standby threshold voltage is 9 V.
standby-resume-
voltage 105: The threshold voltage for resuming
normal operating in standby mode is 10.5 V.
9 IO
Four digital output channels generate output at low level by
default, and the pull-up resistor is disabled.
The pull-up resistor for six digital input channels is disabled.
10 Serial port
RS232
Baud rate: 9600
Data bits: 8 bits
Parity bit: none
Stop bit: 1 bit
RS485
Baud rate: 9600
Data bits: 8 bits
Parity bit: none
Stop bit: 1 bit

Other manuals for InHand VG710