InHand VG710 InVehicle Gateway User Manual
72
9.8 Alarm
The alarm function enables users to identify gateway abnormalities in time. When an abnormality
occurs, the gateway reports an alarm. You can select system-defined abnormalities and choose an
appropriate notification way to obtain the abnormality information. All alarms are recorded in alarm
logs so that users can identify abnormalities and perform troubleshooting in time.
Alarm states:
● Raise: indicates that the alarm has been generated but not been confirmed.
● Confirm: indicates that the alarm cannot be solved currently.
● All: indicates all generated alarms.
Alarm levels:
● EMERG: The device undergoes a serious error that causes a system reboot.
● CRIT: The device undergoes an unrecoverable error.
● WARN: The device undergoes an error that affects system functions.
● NOTICE: The device undergoes an error that affects system performance.
● INFO: A normal event occurs.
(1) Status: Click "Administration >> Alarm >> Status" and view all alarms generated in the system
since power-on.
(2) Alarm Input: Select an alarm type as required. When this item is abnormal, an alarm is generated.
(3) Alarm Output: When an alarm is generated, the system automatically sends the alarm content to
the destination email address via an email. This function is not available for common users. Set the
sender mail address in "Email Alarm" and the receiver mail address in "Mail Address". "Mail Server
IP/Name" can be found on the browser (for example, enter "smtp.exmail.qq.com" if you use a Tencent
Enterprise mailbox.)