Parameter Description MD320/MD320N User Manual
132
F7-11
Software version No.2 Factory default value
Setup range
Software version No. of the motor
control board
Group F8 Auxiliary Function
F8-00
Jog running
frequency
Factory default
value
2.00Hz
Setup range
0.00Hz ~ maximum frequency
F8-01
Jog speed-up time
Factory default
value
20.00s
Setup range 0.00s~ 6500.0s
F8-02
Jog speed-down time
Factory default
value
20.00s
Setup range 0.00s~ 6500.0s
It is used to define the reference frequency and speed-up/speed-down time of the inverter
when jogging. The Jog process is started and stopped according to the start mode 0 (F6-00,
direct start) and the stop mode 0 (F6-10, speed-down time to stop).
The Jog speed-up time means the time required for the inverter to accelerate from 0Hz to the
maximum output frequency (F0-10).
The Jog speed-down time means the time required for the inverter to decelerate from the
maximum output frequency (F0-10)to 0Hz.
F8-03
Speed-up time 2
Factory default
value
20.00s
Setup range 0. 0s~ 6500.0s
F8-04
Speed-down time 2
Factory default
value
20.00s
Setup range 0.0s~ 6500.0s
F8-05
Speed-up time 3
Factory default
value
20.00s
Setup range 0.0s~ 6500.0s
F8-06
Speed-down time 3
Factory default
value
20.00s
Setup range 0.0s~ 6500.0s