EasyManua.ls Logo

Inovance MD300 - Deceleration over Current (ERR03)

Inovance MD300
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault Diagnosis and Solution MD320/MD320N User Manual
162
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
De ce le ration ove r current
Check if the output loop of the
inve rter is earthed or s hort circuited
P e rform trouble shooting
If the motor para me ters a re identified
Identify the motor para me ters
V/F Mode
If the dece le ra tion time is too s hort
Prolong the dece le ra tion time
If the voltage is too low
Adjus t the voltage
to norma l range
If load is added s uddenly
during the dece le ra tion
Re move the additional load
If the bra ke unit and bra ke
re sistor a re ins ta lle d
Ins tall the bra ke unit
and bra ke re sistor
As k for technica l s upport
Fig.8-3 Deceleration over current (ERR03)

Table of Contents

Related product manuals