Maintaining Your Server
Intel® Server Chassis SC5300 User Guide 43
4. Remove the 8 screws holding the Fixed Power Supply shield in place (letter “A”). Remove 2
screws holding the Fixed Power Supply inside the power supply bay (letter “B”). Remove
Fixed Power Supply (letter “C”).
A
C
B
TP00694
Figure 52. Removing Fixed Power Supply
5. Insert new Fixed Power Supply.
6. Secure Fixed Power Supply inside power supply bay with two screws.
7. Secure Fixed Power Supply shield to chassis with eight screws.
8. Route the P1, P2 and P14 cables to the server board.
9. Connect the power cables to the server board, Refer to the Intel® Server Board Quick Start
User’s Guide or User Guide for appropriate power connections.
10. Route the shorter power cables (P3, P4 and P5) to the upper device bay and connect power
cables to installed devices.
11. Route the longest power cables (P8, P9, P10, and P12) to the six-drive bay and connect power
cables to installed devices.
12. Route the P6 and P7 cables to the four-drive bay and connect power cables to installed devices.
13. Route the SATA drive power cables to whichever drive bay is using SATA fixed drives.
14. Replace Primary Access Cover (see “Install Primary Access Cover” in Chapter 2 for step-by-
step instructions).
15. Connect power to the Fixed Power Supply.