138 xGenConnect Installation and Programming Guide
Programming Sequence
6. Communicator
17. Event Lists
5. Channels
a) Options
→
→
→
b) IP Config
c) Ethernet
d) Radio
e) Dial IP
6. Communicator
f) Email
17. Event Lists
g) Remote Access
h) System Event Reporting
18. Channel Groups
18. Channel Groups
Instructions
1. Go to Channels.
2. Enter an Account Number up to 8 digits, hex values are accepted.
3. Select the Format of the communication channel, this will automatically use
the settings programmed for that Format in the Communicator menu.
4. Select the reporting device, by default Device 1 is the xGenConnect panel.
5. Enter the destination phone number, email address or IP address depending
on which Format you selected.
6. Select what events you want to be sent via this Channel by selecting the
appropriate Event List. Events that arrive at this channel will be checked that