EN 50131-3 and EN 50136-2 Compliancy 
In order to be compliant with the technical specification EN 50131-3 (Alarm 
systems – Control and indicating equipment), the following guidelines must be 
taken into account: 
•  The tamper of the warning device should be connected to a 24-hour zone 
input. 
•  Overriding is not supported with xGenConnect. In case a zone is faulted, one 
shall bypass the zone manually before arming or verify the zone and clear the 
fault. See user instructions. 
•  Hold-up zones are not allowed to be set for bypass. 
•  Zone isolation is not supported. 
•  EN 50136-2 (Alarm transmission systems and equipment – Part 2: 
Requirements for Supervised Premises Transceiver (SPT): 
- Upon configuring alarm transmission path and remote connection details, 
default user/installer keys shall be changed. 
Options Affected by EN 50131 Regulations 
EN 50131 Grade 2 Required settings 
The following options and values are mandatory for EN 50131-1 Grade 2 
regulations. 
•  Period, 24 h for every path to meet ATS Class 2, 4 h for the IP path to meet 
Class 4.  
•  View Areas and Control Areas settings are identical 
•  Buzzer silent, never 
•  Quick set, off 
•  Function keys, all set to None 
•  User group options, 25. No OP/CL reports option set to No 
•  Inhibit, set to No for all zones with type 5. Panic, 6. 24H 
•  Swinger shunt, set to Yes for all zones 
•  ACK on keypad, set to None for all zones with type 9. Keyswitch 
•  Entry time, 45 s maximum 
•  Entry alarms, Instant 
•  Active, set to No for all schedules. 
•  Activation, internal and external siren 90 to 900 s 
•  Delay time, external siren 600 s maximum 
•  Armed display, 30 s maximum 
•  Mains reporting delay 10 to 70 s 
•  User code required, enabled 
•  Armed display, always