116 Intermec EasyCoder PF2i, PF4i, and PF4i Compact Industrial—Service Manual
Chapter 9—Label Taken Sensor
9.4 Adjustment
The sensitivity of the Label Taken Sensor (LTS) may need to be adjusted
according to the ambient light conditions and the refl ective characteristics
of the back side of the media.
Fingerprint
The sensitivity can be adjusted in the Setup Mode (see Appendix 1),
or by using setup fi les or setup strings (see Intermec Fingerprint v8.xx,
Programmer’s Reference Manual). In the Setup Mode, the LTS setup options
are only displayed if an optional label taken sensor is installed in the
printer.
• LTS Adjust:
Press <Enter>. A label is fed out. Remove the label and press <Enter>
again. A menu shows the sensitivity automatically selected by the
fi rmware and the range in which the LTS will work. Press <Enter> again
and you will proceed to the LTS Test menu.
• LTS Test:
Press <Enter>. A label is fed out. Remove the label and a new label
should be fed out automatically. Repeat until you are sure the LTS
works properly. Then press <Enter> to stop and exit.
• LTS Value:
Press <Enter>. You can enter a new value in the range indicated in the
LTS Adjust menu (see above). Min/max values are in the range 0-10.
IPL
The sensitivity can be adjusted in the Setup Mode (see Appendix 1).
• In the Setup Mode, select the Confi guration option.
• Select LTS Calibration and press the T key.
• Press <Enter>
• A number of labels are fed out. Remove the labels and press <Enter>.
• The sensor has now been automatically adjusted and the resulting
sensitivity is displayed as a numeric value in the range of 8 to 14.