Chapter 15—Troubleshooting
Description:
No transfer printout.
Possible Causes and Suggested Remedies:
Refer to Chapter 15.12 for general printout troubles.
Bad ribbon load.
- Transfer ribbon loaded incorrectly so the ink-coated side does not face
the receiving face material. Reload ribbon.
Description:
Ribbon fed out in front of printer.
Possible Causes and Suggested Remedies:
Printer is set up for direct thermal printing, but a ribbon is loaded.
- Remove ribbon or change the paper type setup to thermal transfer.
Ribbon rewind motor does not run.
- Cable between ribbon motor and P6 on the Power Supply Unit
broken or not correctly connected?
- Faulty ribbon sensor? See Chapter 15.11.
- Faulty ribbon motor? Replace.
- Faulty CPU board? Replace.
- Faulty Power Supply Unit? Replace.