52 EasyCoder PX6i User’s Guide (Fingerprint version)
Chapter 6 — Setting Up the Printer
Character Length
The character length specifi es the number of bits that will defi ne a
character. Eight bits are recommended, because that option allows more
special characters and characters specifi c for foreign languages to be used.
Refer to the Intermec Fingerprint v8.3x, Programmers Reference Manual
for more information.
7 Characters ASCII 000 to 127 decimal
8 Characters ASCII 000 to 255 decimal (default)
Parity
The parity decides how the fi rmware will check for transmission errors.
There are fi ve options:
• None (default)
• Even
• Odd
• Mark
• Space
Stop Bits
The number of stop bits specifi es how many bits will defi ne the end of a
character. There are two options:
• 1 (default)
• 2
Flow Control
RTS/CTS is a protocol where the communication is controlled by cur-
rents through separate lines in the cable being set either to high or low.
By default, this option is disabled.
RTS high indicates that the transmitting unit is able to receive characters.
RTS low indicates that the receive buffer is fi lled to 75% (see XON/
XOFF).
CTS high indicates that the unit transmitting the CTS signal is ready to
receive data. CTS low indicates that the receive buffer is full (see XON/
XOFF). In some computer programs, for example MS Windows Termi-
nal, RTS/CTS is designated “Hardware.”
ENQ/ACK is a protocol where the communication is controlled by
the control characters ENQ (ASCII 05 dec.) and ACK (ASCII 06 dec.)
being transmitted on the same line as the data. The sending unit trans-
mits ENQ at regular intervals. If the response ACK is not received, the

Table of Contents

Other manuals for Intermec EasyCoder PX6i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PX6i and is the answer not in the manual?

Intermec EasyCoder PX6i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
DisplayLCD
Product colorSilver
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Media thickness2.4/10 mm
Maximum label width170 mm
Maximum label length4 m
Maximum roll diameter213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Power requirements90 - 265 VAC, 45 - 65Hz
Power consumption (standby)20 W
Power consumption (printing)125 W
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth482 mm
Width238 mm
Height335 mm
Weight14800 g